2019-01-05 11:33
User: Changge Hengyuan Wood Industry Name: Intelligent Filter Compensation Module Model: ZBMGD-33.3/0.4 ZBMGD-66.7/0.4 Load: air compressor, motor with frequency converter 1. Power factor: increase the power factor of the system, the monthly average power factor is not less than 0.92; 2. Filtering effect: The total harmonic current total content decreased from 10.4% to 3.3%; 3. Temperature noise: The temperature and noise of the transformer are significantly reduced, so that the transformer capacity is fully utilized;
Hunan Songyuan Chemical Co., Ltd.

Hunan Songyuan Chemical Co., Ltd.

Release time:
2019-01-05 11:32
User: Hunan Songyuan Chemical Co., Ltd. Name: Intelligent Filter Compensation Module Model: ZBMGD-33.3/0.4 Load: air compressor, motor with frequency converter 1. Power factor: increase the power factor of the system, the monthly average power factor is not less than 0.92; 2. Filtering effect: Total harmonic current drops from 400A to 330A 3. Temperature noise: The temperature and noise of the transformer are significantly reduced, so that the transformer capacity is fully utilized;
Active Filtering Typical Case - Case 12

Active Filtering Typical Case - Case 12

Release time:
2019-01-05 11:21
Oilfield Harmonic Treatment Program: Background of the project: The main load of the oil field is the mud pump and drilling equipment with speed control equipment. Since the speed regulating equipment is a non-linear load, it will inevitably produce severe voltage and current distortion, which often causes the logging recorder to record errors or data inaccuracy. Our company conducted on-site data testing for the 50DB and 70DB power supply systems of Daqing Oilfield, the 50DB and 70DB power supply systems of Changqing Oilfield in Shaanxi, and the 90DB power supply system of Xinjiang Karamay Oilfield. The data analysis shows that the cause of serious power quality problems is mud. During the working process of the pump and drilling equipment, the harmonic voltage generated affects the normal operation of the logging tool, so harmonic management must be carried out. Reconstruction plan: Through on-site power quality diagnosis, our company has proposed an active voltage quality controller (AVQR) that is independently developed and produced to solve the problems of harmonics, fluctuations, flicker, instantaneous interruption of the logging voltage of the logging instrument, and makes the logging instrument reliable. , the record is accurate. Effectiveness analysis:
Qinhuangdao Boye Glass Co., Ltd.

Qinhuangdao Boye Glass Co., Ltd.

Release time:
2019-01-05 11:20
Typical case of harmonic treatment in glass factory (Qinhuangdao Boye Glass Co., Ltd.) Background of the project: At present, a glass 10kV substation mainly has a transformer with a capacity of 1000kVA and 10kV/0.4kV. The main load is a general AC load, but a high-power inverter is used in air-cooled cooling glass. After the glass is output from the tempering furnace, the fan starts to work. This working process is always cycled. During the operation of the fan, the current distortion of the grid is very high. Governance plan: According to the comprehensive consideration of the field test data, a SPA3-100/0.4 active power filter is selected to compensate the harmonics in the power grid to achieve the purpose of effective harmonic control. Governance effect: